UAD1086
FATALOfficial message text · Appendix H-1: UAD Compliance Rules — URAR, v1.5
The number of living units in the structure does not equal the number of units delivered in the UAD XML for the structure. For assistance with this message, contact the appraisal software vendor.
Fatal — a single unresolved Fatal makes the entire submission come back NOT SUCCESSFUL (UCDP Hard Stop 401).
What triggers UAD1086
The published rule logic, verbatim:
For each IMPROVEMENT, if LivingUnitCount <> the number of instances of PROPERTY_UNIT
- • Checked for the Subject property.
- • Bound to MISMO data point
LivingUnitCountat../VALUATION_ANALYSIS/PROPERTIES/PROPERTY/IMPROVEMENTS/IMPROVEMENT/STRUCTURE/STRUCTURE_DETAIL/
How to fix it
This requirement applies to the XML data itself. Your form software populates it from the report data; correct the underlying entry, regenerate the package, and re-check.
Because this is a Fatal edit, do not submit until it is resolved — one Fatal bounces the whole package.
UAD1086 is in UADCheck's reference library; automated coverage for it is on the roadmap. The inspection already runs the full GSE schema, the package-integrity layer, and every auto-checkable compliance rule — each report states exactly what was covered.
Begin inspection →Related messages
- UAD1084 FatalProvide the number of living units in the structure.…
- UAD1085 FatalThe number of living units cannot be 0 for any dwelling.…
- UAD1693 FatalThe number of 'Accessory Dwelling Units' plus the number of 'Units Exc…
- UAD1047 FatalIndicate whether the structure is a 'Dwelling' or 'Outbuilding'.…
- UAD1089 FatalProvide the heating system type. Select 'None' if there is no heating …
- UAD1090 FatalProvide a description when heating system type = 'Other'.…
Source: Appendix H-1: UAD Compliance Rules — URAR, v1.5 (public GSE document). Verified against the published spreadsheet; not affiliated with Fannie Mae or Freddie Mac.