UAD1559
FATALOfficial message text · Appendix H-1: UAD Compliance Rules — URAR, v1.5
Provide the manner in which the interior inspection was conducted by the Appraiser and/or Supervisory Appraiser.
Fatal — a single unresolved Fatal makes the entire submission come back NOT SUCCESSFUL (UCDP Hard Stop 401).
What triggers UAD1559
The published rule logic, verbatim:
If PropertyInteriorInspectionMethodType is not provided in a given instance of INSPECTION_DETAIL
- • Checked for the Subject property.
- • Bound to MISMO data point
PropertyInteriorInspectionMethodTypeat../VALUATION_ANALYSIS/PROPERTIES/PROPERTY/INSPECTIONS/INSPECTION/INSPECTION_DETAIL/
How to fix it
On the URAR, this lives at: Assignment Information → Contact Information → Interior. Complete or correct that field in your form software, regenerate the package, and re-check before submission.
Because this is a Fatal edit, do not submit until it is resolved — one Fatal bounces the whole package.
UAD1559 is in UADCheck's reference library; automated coverage for it is on the roadmap. The inspection already runs the full GSE schema, the package-integrity layer, and every auto-checkable compliance rule — each report states exactly what was covered.
Begin inspection →Related messages
- UAD1522 FatalProvide the manner in which the Property Data Collector conducted the …
- UAD1212 WarningProvide the federal agency (i.e., VA, USDA, FHA) for which the apprais…
- UAD1219 FatalProvide the 'Assignment Reason'.…
- UAD1220 FatalProvide a description when 'Assignment Reason' = 'Other'.…
- UAD1221 WarningProvide the date the property inspection was performed.…
- UAD1222 FatalProvide the 'Property Valuation Method'.…
Source: Appendix H-1: UAD Compliance Rules — URAR, v1.5 (public GSE document). Verified against the published spreadsheet; not affiliated with Fannie Mae or Freddie Mac.