UAD1656
FATALOfficial message text · Appendix H-1: UAD Compliance Rules — URAR, v1.5
Provide either an image of the price trend graph or price trend analysis commentary.
Fatal — a single unresolved Fatal makes the entire submission come back NOT SUCCESSFUL (UCDP Hard Stop 401).
What triggers UAD1656
The published rule logic, verbatim:
If PriceTrendsAnalysisDescription is not provided, and ImageCategoryType = "PriceTrendGraph" is not provided in any instance of IMAGE
- • Checked for the Subject property.
- • Bound to MISMO data point
ImageCategoryTypeat../VALUATION_ANALYSIS/PROPERTIES/PROPERTY/INSPECTIONS/INSPECTION/IMAGES/IMAGE/
How to fix it
On the URAR, this lives at: Market → Search Result Metrics → Graph. Complete or correct that field in your form software, regenerate the package, and re-check before submission.
Because this is a Fatal edit, do not submit until it is resolved — one Fatal bounces the whole package.
UAD1656 is in UADCheck's reference library; automated coverage for it is on the roadmap. The inspection already runs the full GSE schema, the package-integrity layer, and every auto-checkable compliance rule — each report states exactly what was covered.
Begin inspection →Related messages
- UAD1274 FatalThe required subject property photos must be included.…
- UAD1275 FatalProvide a photo of each sales comparable used in the valuation.…
- UAD1278 FatalProvide a photo of the water frontage.…
- UAD1280 WarningProvide a photo of each GRM comparable used in the valuation.…
- UAD1283 FatalProvide the sales comparable map.…
- UAD1284 FatalProvide an image of the manufactured home HUD certification label.…
Source: Appendix H-1: UAD Compliance Rules — URAR, v1.5 (public GSE document). Verified against the published spreadsheet; not affiliated with Fannie Mae or Freddie Mac.