UAD1073
WARNINGOfficial message text · Appendix H-1: UAD Compliance Rules — URAR, v1.5
Provide the estimated age of the roof.
Warning — the submission can still come back Successful, but the finding is surfaced to your lender's review team.
What triggers UAD1073
The published rule logic, verbatim:
If ImprovementComponentType = "Roof" and RoofEstimatedAgeRangeType is not provided in ROOF_DETAIL
- • Checked for the Subject property.
- • Bound to MISMO data point
RoofEstimatedAgeRangeTypeat../VALUATION_ANALYSIS/PROPERTIES/PROPERTY/IMPROVEMENTS/IMPROVEMENT/STRUCTURE/STRUCTURE_COMPONENTS/STRUCTURE_COMPONENT/ROOF/ROOF_DETAIL/
How to fix it
On the URAR, this lives at: Dwelling Exterior → Quality and Condition → Detail. Complete or correct that field in your form software, regenerate the package, and re-check before submission.
UAD1073 is in UADCheck's reference library; automated coverage for it is on the roadmap. The inspection already runs the full GSE schema, the package-integrity layer, and every auto-checkable compliance rule — each report states exactly what was covered.
Begin inspection →Related messages
- UAD1048 FatalAt least one structure on the property must be identified as a 'Dwelli…
- UAD1050 FatalProvide 'Year Built' for each dwelling.…
- UAD1052 WarningThe 'Year Built' is prior to 1800. Please check for accuracy.…
- UAD1053 WarningThe 'Year Built' for a dwelling cannot be after 'Effective Date of App…
- UAD1054 WarningFor each dwelling indicate whether the 'Year Built' was estimated.…
- UAD1060 FatalProvide 'Structure Design' (e.g., Low-rise, Mid-rise, High-rise, Rowho…
Source: Appendix H-1: UAD Compliance Rules — URAR, v1.5 (public GSE document). Verified against the published spreadsheet; not affiliated with Fannie Mae or Freddie Mac.