Dwelling Exterior
Messages51Of which Fatal31
- FRE50002SEVEREThe appraisal report indicates component conditions of Exterior Features that are not cons…
- FRE54101WARNINGThe appraisal report indicates that within the Exterior Features table the Exterior Walls …
- FRE54102WARNINGThe appraisal report indicates that within the Exterior Features table the Foundation Cond…
- FRE54103WARNINGThe appraisal report indicates that within the Exterior Features table the Roof Condition …
- FRE54104WARNINGOne of the following messages is returned: • The appraisal report indicates that within t…
- FRE54310WARNINGA dwelling [StructureIdentifier] Exterior Condition Rating is reported as [XX] but the fol…
- FRE65140WARNINGThe appraisal report indicates that the dwelling on the subject property was built in [X].…
- FRE70002SEVEREThe appraisal report indicates that the subject's construction method is Container.
- FRE70003SEVEREThe appraisal report indicates that the subject's construction method is Three Dimensional…
- FRE70004SEVEREThe appraisal report indicates that the subject construction method is Manufactured. Manuf…
- FRE70005SEVEREThe appraisal report indicates that the subject construction method is Other. A property w…
- FRE76118FATALThe appraisal report indicates that the Exterior Quality Rating is Q6. Please refer to the…
- FRE76119FATALThe appraisal report indicates that the Exterior Condition Rating is [X]. Please refer to …
- FRE76124FATALThe appraisal report indicates that the Lack of Heating System is not Typical for the Mark…
- UAD1048FATALAt least one structure on the property must be identified as a 'Dwelling'.
- UAD1050FATALProvide 'Year Built' for each dwelling.
- UAD1052WARNINGThe 'Year Built' is prior to 1800. Please check for accuracy.
- UAD1053WARNINGThe 'Year Built' for a dwelling cannot be after 'Effective Date of Appraisal'.
- UAD1054WARNINGFor each dwelling indicate whether the 'Year Built' was estimated.
- UAD1060FATALProvide 'Structure Design' (e.g., Low-rise, Mid-rise, High-rise, Rowhouse / Townhouse, Sem…
- UAD1061FATALProvide a description when 'Structure Design' = 'Other'.
- UAD1062FATALProvide 'Construction Method' (e.g., Site Built, Manufactured, Modular) for each dwelling.
- UAD1063FATALProvide a description when 'Construction Method' = 'Other'.
- UAD1065FATALThe exterior feature type must be included. For assistance with this message, contact the …
- UAD1066FATALProvide a description when 'Feature Type' = 'Other'.
- UAD1067FATALProvide the foundation details (e.g., style, material) for the structure.
- UAD1068FATALProvide the materials used for the foundation.
- UAD1069FATALProvide a description when foundation material = 'Other'.
- UAD1070FATALProvide the type of foundation.
- UAD1071FATALProvide a description when foundation type = 'Other'.
- UAD1072FATALProvide the roof details (e.g., estimated age, material) for the structure.
- UAD1073WARNINGProvide the estimated age of the roof.
- UAD1074FATALIndicate whether the roof is observable.
- UAD1075WARNINGProvide the roof material.
- UAD1076FATALProvide a description when roof material = 'Other'.
- UAD1077WARNINGProvide additional description for the exterior feature being referenced.
- UAD1078FATALProvide the 'Condition Status'.
- UAD1079FATALProvide the exterior walls and trim details (e.g., material) for the structure.
- UAD1080FATALProvide the exterior wall material type.
- UAD1081FATALProvide a description when exterior wall material = 'Other'.
- UAD1082FATALIndicate whether the rowhouse / townhouse is an end unit.
- UAD1085FATALThe number of living units cannot be 0 for any dwelling.
- UAD1087WARNINGProvide the number of 'Floors in Building'.
- UAD1088WARNINGIndicate whether the factory-built certification has been examined for an on-frame modular…
- UAD1091FATALWhen 'Units Excluding ADUs' is more than 1, the structure identifier must be provided for …
- UAD1092FATALThe structure identifier must be unique.
- UAD1098FATALIndicate whether the core heating system for dwelling is located below grade.
- UAD1099WARNINGProvide the approximate elevation range from grade level to the bottom of the front entran…
- UAD1382FATALProvide the exterior condition rating.
- UAD1383FATALProvide the exterior quality rating.
- UAD1687FATALIndicate whether any defects, damages, or deficiencies are observed on the exterior of the…
Stop looking codes up one at a time — attach your package and get every finding at once, free.
Begin inspection →