Unit Interior
Messages60Of which Fatal49
- FRE43670WARNINGA dwelling (StructureIdentifier) is reported as [X] years old and the Unit [UnitIdentifier…
- FRE50003SEVEREThe appraisal report indicates component conditions of Unit Interior features are not cons…
- FRE54320WARNINGOne of the following messages is returned: • The level type of [LevelType] does not match…
- FRE76001FATALThe appraisal report indicates that the ADU Finished Area Above Grade is less than 400 sq.…
- FRE76002FATALThe appraisal report indicates that the Dwelling Finished Area Above Grade is less than 60…
- FRE76137SEVEREThe appraisal report indicates that there is less than one Full Bathroom in the Living Uni…
- FRE76138FATALThe appraisal report indicates that the Interior Quality Rating is Q6. Please refer to the…
- FRE76139FATALThe appraisal report indicates that the Interior Condition Rating is [X]. Please refer to …
- UAD1138FATALProvide the type of accessibility feature. Select 'None' if there are no accessibility fea…
- UAD1139FATALProvide the primary exterior access method (e.g., walk-out, walk-up) for the below grade a…
- UAD1140FATALProvide a description when 'Grade Level' = 'Other'.
- UAD1141FATALProvide the Grade Level Type (i.e., Above Grade, Fully Below Grade, Partially Below Grade)…
- UAD1142FATALProvide the level type (e.g., Level 1, Level 2, Level B1).
- UAD1143WARNINGProvide at least one instance of 'Kitchen' for each living unit.
- UAD1144FATALProvide a description when room type = 'Other'.
- UAD1145FATALProvide the 'Condition Status' for the room.
- UAD1146FATALProvide the 'Update Status' for the room.
- UAD1147FATALProvide the timeframe in which the room was updated.
- UAD1148FATALThe interior feature type must be included.
- UAD1149FATALProvide the flooring details (e.g., material, condition) for the living unit.
- UAD1150FATALProvide the flooring material(s).
- UAD1151FATALProvide a description when flooring material = 'Other'.
- UAD1152FATALProvide the walls and ceiling details (e.g., style, height) for the living unit.
- UAD1153FATALProvide a description when 'Feature Type' = 'Other'.
- UAD1154FATALProvide the approximate ceiling height(s) for the living unit.
- UAD1155WARNINGProvide additional description for the interior feature being referenced.
- UAD1156FATALProvide the 'Condition Status'.
- UAD1157FATALIndicate whether the subject property is a corner unit.
- UAD1158FATALProvide the 'Floor Number'.
- UAD1160FATALProvide the interior condition rating.
- UAD1161FATALProvide the interior quality rating.
- UAD1162WARNINGIndicate whether the living unit utilities are metered separately.
- UAD1163FATALIndicate whether ADUs are typical to the market.
- UAD1164FATALIndicate whether the living unit is an ADU.
- UAD1165FATALIndicate whether the ADU has a separate postal address.
- UAD1166FATALProvide ingress/egress to the ADU (i.e., Interior Access Only, Exterior Access Only, Inter…
- UAD1167FATALIndicate whether the ADU is legally rentable.
- UAD1168FATALIndicate whether the living unit has any Live/Work space.
- UAD1169FATALProvide the 'Condition Status' for each floor covering.
- UAD1170FATALUnit Identifier must be provided when multiple living units are identified in the appraisa…
- UAD1171FATALThe unit identifier must be unique.
- UAD1173FATALProvide the 'Overall Update Status for Bathrooms'.
- UAD1174FATALProvide the number of bedrooms in the living unit, even if the value is 0.
- UAD1175FATALProvide the number of full bathrooms in the living unit, even if the value is 0.
- UAD1176FATALProvide the number of half bathrooms in the living unit, even if the value is 0.
- UAD1177FATALProvide the level type (e.g., Level 1, Level 2, Level B1).
- UAD1178FATALProvide the 'Overall Update Status for Flooring'.
- UAD1182WARNINGIndicate whether the living unit has any non-residential uses.
- UAD1184FATALProvide the finished area of each level in the living unit.
- UAD1185WARNINGProvide the unfinished area of each level in the living unit.
- UAD1186FATALProvide the 'Finished Above Grade' Area, even if the value is 0.
- UAD1187FATALProvide the 'Finished Above Grade (Nonstandard)' Area, even if the value is 0.
- UAD1188WARNINGProvide the 'Unfinished Above Grade' Area, even if the value is 0.
- UAD1189FATALProvide the 'Finished Below Grade' Area, even if the value is 0.
- UAD1190FATALProvide the 'Unfinished Below Grade' Area, even if the value is 0.
- UAD1484FATALProvide the 'Finished Below Grade (Nonstandard)' Area, even if the value is 0.
- UAD1688FATALIndicate whether the living unit has any defects, damages, or deficiencies.
- UAD1694FATALEach dwelling must contain at least one living unit that is not an ADU.
- UAD1730WARNINGThere is an indicator of a living unit in an outbuilding, and it was not identified as an …
- UAD1764FATALEach dwelling must contain at least one living unit.
Stop looking codes up one at a time — attach your package and get every finding at once, free.